ECG vs. single-antenna system for heartbeat activity detection

Published: 26 October 2011 Publication History

Abstract

This paper presents a single antenna Doppler system for contact-less heartbeat monitoring. The proposed system, based on using a vector network analyzer, is tested at 16 GHz frequency for different transmitted power levels between 0 and -25 dBm. Both heartbeat rate and heart rate variability are extracted from the signals obtained with the Doppler system and compared to simultaneous ECG signals.

References

[1]
H-R. Chuang, Y. Chen, and K.-M. Chen, "Automatic clutter-canceler for microwave life-detection systems," IEEE Transactions on Instrumentation and Measurement, vol. 40, no. 4, pp. 747--750, Aug. 1991.
[2]
J. C. Lin, "Microwave sensing of physiological movement and volume change: A review," Bioelectromagnetics (1992), vol. 13, pp. 557--565.
[3]
A. De Groote, M. Wantier, G. Cheron, M. Estenne, and M. Paiva, "Chest wall motion during tidal breathing," Journal of Applied Physiology (1997), vol. 83, no. 5, pp. 1531--1537.
[4]
G. Ramachandran and M. Singh, "Three-dimensional reconstruction of cardiac displacement patterns on the chest wall during the P, QRS, and T-segments of the ECG by laser speckle interferometry," Medical and Biological Engineering and Computing (1989), vol. 27, no. 5, pp. 525--530.
[5]
F. Mohammad-Zahed, F. Taghibakhsh and B. Kaminska, "Contactless Heart Monitoring," 2007 IEEE, Session 33: Biomedical Signal Processing-I, pp. 583--585.
[6]
K. M. Chen, Y. Huang, J. Zhang, and A. Norman, "Microwave life-detection systems for searching human subjects under earthquake rubble and behind barrier", IEEE Trans. Biomed. Eng. Jan. 2000, vol. 47, no. 1, pp. 105--114.
[7]
A. D. Droitcour, V. M. Lubecke, J. Lin, and O. Boric-Lubecke, "A microwave radio for Doppler radar sensing of vital signs," in IEEE MTT-S Int. Microw. Symp. Dig., May 2001, pp. 175--178.
[8]
A. D. Droitcour, O. Boric-Lubecke, V. M. Lubecke, and J. Lin, "0.25 μm CMOS and BiCMOS single chip direct conversion Doppler radars for remote sensing of vital signs," in IEEE Int. Solid-State Circuits Conf. Tech. Dig., Feb. 2002, pp. 348--349.
[9]
O. Boric-Lubecke, G. Awater, and V. M. Lubecke, "Wireless LAN PC Card Sensing of Vital Signs," IEEE Topical Conference on Wireless Communication Technology (2003), pp. 206--207.
[10]
Y. Xiao, J. Lin, O. Boric-Lubecke, and V. M. Lubecke, "A Ka-band low power Doppler radar system for remote detection of cardiopulmonary motion," presented at the 27th IEEE Annu. Eng. Med. Biol. Soc. Conf., Sep. 1--4, 2005.
[11]
C. Gu, C. Li, J. Lin, J. Long, J. Huangfu, and L. Ran, "Instrument-Based Noncontact Doppler Radar Vital Sign Detection System Using Heterodyne Digital Quadrature Demodulation Architecture," IEEE Transactions on Instrumentation and Measurement, Vol. 59, No. 6, pp. 1580--1588, June 2010.
[12]
V. M. Lubecke, O. B. Lubecke, A. H. Madsen, and A. E. Fathy, "Through-the-wall radar life detection and monitoring," in IEEE International Microwave Symposium, 2007, pp. 769--772.
[13]
C. Li and J. Lin, "Random body movement cancellation in doppler radar vital sign detection," IEEE Trans. on Microw. Theory Techn., vol. 56, pp. 3143--3152, 2008.
[14]
I. V. Mikhelson, S. Bakhtiari, T. W. Elmer, and A. V. Sahakian, "Remote sensing of heart rate and patterns of respiration on a stationary subject using 94-GHz millimeter-wave interferometry," IEEE Transactions on Biomedical Engineering, Vol. 58, Issue 6, pp. 1671--1677, 2011.
[15]
D. Obeid, S. Sadek, G. Zaharia, and G. El Zein, "Non-Contact Heartbeat Detection at 2.4, 5.8 and 60 GHz: A Comparative Study," Microwave Opt. Technol. Lett., vol. 51, no. 3, pp. 666--669, March 2009.
[16]
D. Obeid, S. Sadek, G. Zaharia, and G. El Zein, "Multitunable Microwave System for Touchless Heartbeat Detection and Heart Rate Variability Extraction," Microwave Opt. Technol. Lett., vol. 52, no. 1, pp. 192--198, Jan. 2010.
[17]
D. Obeid, S. Sadek, G. Zaharia, and G. El Zein, "Low Power Microwave Systems for Heartbeat Rate Detection at 2.4, 5.8, 10 and 16 GHz, Proc. of the International Conference on Applied Sciences in Biomedical and Communication Technologies, ISABEL 2008, Aalborg, Denmark, October 25--28, 2008.
[18]
P. Joseph, U. R. Acharya, C. K. Poo, J. Chee, L. C. Min, S. S. Iyengar, and H. Wei, "Effect of reflexological stimulation on heart rate variability," ITBM-RBM, vol. 25, pp. 40--45, 2004

Cited By

View all

Recommendations

Comments

Information & Contributors

Information

Published In

cover image ACM Other conferences
ISABEL '11: Proceedings of the 4th International Symposium on Applied Sciences in Biomedical and Communication Technologies
October 2011
949 pages
ISBN:9781450309134
DOI:10.1145/2093698
Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

Sponsors

  • Universitat Pompeu Fabra
  • IEEE
  • Technical University of Catalonia Spain: Technical University of Catalonia (UPC), Spain
  • River Publishers: River Publishers
  • CTTC: Technological Center for Telecommunications of Catalonia
  • CTIF: Kyranova Ltd, Center for TeleInFrastruktur

Publisher

Association for Computing Machinery

New York, NY, United States

Publication History

Published: 26 October 2011

Permissions

Request permissions for this article.

Check for updates

Author Tags

  1. Doppler radar
  2. heart rate variability
  3. heartbeat rate
  4. touch-less detection

Qualifiers

  • Research-article

Funding Sources

Conference

ISABEL '11
Sponsor:
  • Technical University of Catalonia Spain
  • River Publishers
  • CTTC
  • CTIF

Contributors

Other Metrics

Bibliometrics & Citations

Bibliometrics

Article Metrics

  • Downloads (Last 12 months)0
  • Downloads (Last 6 weeks)0
Reflects downloads up to 06 Jan 2025

Other Metrics

Citations

Cited By

View all

View Options

Login options

View options

PDF

View or Download as a PDF file.

PDF

eReader

View online with eReader.

eReader

Media

Figures

Other

Tables

Share

Share

Share this Publication link

Share on social media