MICROTEST 6632 Impedance Analyzer offers a wide frequency range of 10Hz to 50MHz for measuring the impedance characteristics of components and materials. The measured parameters include |Z| (impedance), |Y| (admittance), θ (phase angle), X (reactance), R (series/parallel resistance), G (conductance), B (Susceptance), L (inductance), D (dissipation factor), Q (quality factor), DCR (DC resistance), C (capacitance), ESR (equivalent series resistance), ε (relative permittivity), and μr (relative permeability). It supports both Meter mode and Sweep Analysis mode, allowing measurement results to be displayed in numeric or graphical formats. It supports LAN/USB Host/USB Device/GPIB/RS-232 communication interfaces, making it compatible with automation equipment or human-machine interfaces (PLC).
Selection
6632 Series | |||||||
Model | 6632-1 | 6632-3 | 6632-5 | 6632-10 | 6632-20 | 6632-30 | 6632-50 |
Frequency |
10Hz- 1MHz |
10Hz- 3MHz |
10Hz- 5MHz |
10Hz- 10MHz |
10Hz- 20MHz |
10Hz- 30MHz |
10Hz- 50MHz |
SPEC
Model | 6632 | |
Frequency Range | 10Hz-50MHz | |
Frequency Setting | Continuity | |
Frequency Resolution | 100mHz, 6-bit Frequency Input | |
Frequency Output Accuracy | ±0.01% | |
Basic Accuracy | ±0.08% (typical ±0.05%) | |
AC Drive Level | Test Signal Voltage Level |
10mV - 2Vrms(100Ω) 10mV - 1Vrms(25Ω) |
Voltage Minimum Resolution | 1mV | |
Accuracy |
ALC ON:6% * Voltage ±2mV ALC OFF:10% * Voltage ±2mV |
|
Test Signal Current Level | 200µA - 20mArms | |
Current Minimum Resolution | 10µA | |
Accuracy |
ALC ON:6% * Current ± 20µA ALC OFF:10% * Current ± 20µA |
|
DC Drive Level | 1V (fixed) | |
Output Impedance | 25Ω/100Ω (switchable) | |
DC Bias Voltage |
Built-in ±12V (100Hz-50MHz) |
External Voltage Bias (±12V/±40V/±600V/±2000V) |
DC Bias Current |
Option DC Bias Current Source (20A/60A/120A/320A) |
External Voltage Bias (100mA) |
Measurement Mode | Meter mode, list mode, sweep mode, and optional equivalent circuit analysis function (S model) | |
Measurement Parameters |
|Z|、|Y|、θ、X、R、G、B、L、D、Q、DCR、C、 ESR、εr 、μr |
|
Test Time (Fastest) | < 3mS |
Measurement Parameters
Parameters | Range |
|Z| | 0.000 mΩ to 9999.99 MΩ |
R, X | ± 0.000 mΩ to 9999.99 MΩ |
|Y| | 0.00000 μS to 999.999 kS |
G, B | ± 0.00000 μS to 999.999 kS |
θRAD | ± 0.00000 to 3.14159 |
θDEG | ± 0.000° to 180.000° |
Cs, Cp | ± 0.00000 pF to 9999.99 F |
Ls, Lp | ± 0.00 nH to 9999.99 kH |
D | 0.00000 to 9999.99 |
Q | 0.00 to 9999.99 |
Δ | ± 0.00% to 9999.99% |
Rdc | 0.00 mΩ to 99.9999 MΩ |
εr' εr'' | 0 to 100000 |
μr' μr'' | 0 to 100000 |
System
Measurement Circuit | Series/Parallel |
Correction | Open Circuit/Short Circuit/Load correction |
Cable Compensation | 0 / 0.5 / 1 /2 (m) |
BIN | ABS、ΔABS、Δ%、OFF |
Comparator | 9 |
List Mode | 50 groups of Multi-steps setting (Each group contains up to 15 steps) |
Bulit-in Storge | 100 sets LCR setting documents, 50 groups of list mode setting |
USB Host Storge | LCR setting documents, list mode setting document, BMP graphics, Sweep screen and test result data |
Trigger Test | Auto, manual, RS-232, GPIB, Handler |
Power Supply | Voltage:90-264Vac |
Frequency:47-63Hz | |
Power consumption | 30VA |
Environment | Temperature:10℃-40℃ |
Humidity:20-90%RH | |
Dimension | 336x147x340 mm (W*H*D) |
Weight | 3.95 Kg |
Interface | RS-232、Handler、LAN、USB Host、USB Device |
Display | Color Screen, 7" TFT (800*480) |