Skip to main content

Erratum to: Improving protein order-disorder classification using charge-hydropathy plots

The Original Article was published on 16 December 2014

During the production of our manuscript [1], an incorrect Figure 1 was put in place of the one we submitted, and we erred in not appropriately informing the production staff of this mistake. The corrected figure and the text describing this figure, as well as the figure legend, are present herein.

Figure 1.
figure 1

Charge-Hydropathy plots. In (A) the IDP-Hydropathy scale was used, in (B) the Guy (1985) Hydropathy scale was used, and in (C) the Kyte-Doolittle (1981) hydropathy scale was used. Red circles indicate disordered proteins, blue circles indicate structured proteins. For these plots, each scale was normalized to be in the interval of 0 to 1. The Guy’s scale is multiplied by -1 prior to normalization to conform to the energy rule set by Kyte-Doolittle scale. In (A) the function describing the boundary is: <charge> = 3.31 <hydropathy> 0.97. In (B) the function describing the boundary is: <charge> = 2.32 <hydropathy> 0.93. In (C), the function describing the boundary is: <charge> = 1.35 <hydropathy> 0.49.

As stated in our manuscript [1], “The C-H plots generated using scale SVM parameters scale, Kyte-Doolittle hydropathy scale, and Guy hydropathy scale for whole protein prediction are shown in Figure 1. Figure 1A, which is derived by SVM parameters scale, shows many fewer misclassified disordered proteins on the ordered side, compared to Figure 1B and 1C.”

As further stated in reference [1]: “Figure 1. Charge-Hydropathy plots. In (A) the IDP-Hydropathy scale was used, in (B) the Guy (1985) Hydropathy scale was used, and in (C) the Kyte-Doolittle (1981) hydropathy scale was used. Red circles indicate disordered proteins, blue circles indicate structured proteins. For these plots, each scale was normalized to be in the interval of 0 to 1. The Guy’s scale is multiplied by -1 prior to normalization to conform to the energy rule set by Kyte-Doolittle scale. In (A) the function describing the boundary is: <charge> = 3.31 < hydropathy> -0.97. In (B) the function describing the boundary is: <charge> = 2.32 < hydropathy> -0.93. In (C), the function describing the boundary is <charge> = 1.35 < hydropathy> -0.49.”

For more details, the reader is referred to the published manuscript [1].

Reference

  1. Huang F, Oldfield CJ, Xue B, Hsu WL, Meng J, Liu X, Shen L, Romero P, Uversky VN, Dunker AK. IDP hydropathy: A new hydropathy scale that improves disorder prediction. BMC Bioinformatics. 2014;15 Suppl 17:54.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. Keith Dunker.

Additional information

The online version of the original article can be found under doi:10.1186/1471-2105-15-S17-S4.

Rights and permissions

Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Huang, F., Oldfield, C.J., Xue, B. et al. Erratum to: Improving protein order-disorder classification using charge-hydropathy plots. BMC Bioinformatics 16, 241 (2015). https://doi.org/10.1186/s12859-015-0646-5

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/s12859-015-0646-5