2024 HVAC Efficiency Standards for Homeowners

HVAC efficiency isn’t what it used to be—and that’s a good thing

A climate control system
Photo: Photo by Alex Tihonov / Moment / Getty Images
A climate control system
Photo: Photo by Alex Tihonov / Moment / Getty Images
Mariel Loveland
Written by Mariel Loveland
Contributing Writer
Updated January 3, 2024

Highlights

  • Regional SEER ratings for cooling systems will increase by 1 SEER. 

  • Heating efficiency will increase from 8.2 HSPF to 8.8 HSPF. 

  • Furnace rating standards will be 81% AFUE for all three regions.

  • HVAC systems are switching to the SEER2, EER2, and HSPF2 standards.

Get quotes from up to 3 pros!
Enter a zip below and get matched to top-rated pros near you.

When looking for a new HVAC system, you’ll need to be able to tell your SEER from your EER. In 2023, HVAC efficiency standards underwent some major changes—which happens every few years as the U.S. Department of Energy (DOE) requires manufacturers to step up their HVAC game. While the changes won’t really affect homeowners who aren’t looking to replace their system, there are a couple of things you need to know for 2024.

What Are HVAC Energy Efficiency Standards?

Since 1992, the DOE has regulated HVAC equipment with minimum efficiency requirements. This pushes manufacturers to make the most energy-efficient products possible, and homeowners can enjoy HVAC tax credits by upgrading their systems. Overall, it’s better for the environment and your utility bills.

Certain metrics measure HVAC efficiency. Most homeowners are familiar with minimum SEER ratings, but there are a handful of different metrics depending on the type of HVAC system: 

  • Seasonal energy efficiency ratio (SEER): What does SEER mean in practice? This metric measures how efficiently your AC unit or heat pump cools your home. The higher the rating, the better the efficiency.

  • Energy Efficiency Ratio (EER): Similar to SEER, EER measures the cooling capacity of your AC or heat pump. Specifically, it weighs the cooling output (BTU) against the energy input (watts).

  • Heating seasonal performance factor (HSPF): This factor measures how much energy your heat pump uses to heat your home.

  • Annualized fuel utilization efficiency (AFUE): Furnaces are rated by how much heat they produce per dollar of fuel. 

You may notice these ratings called SEER2, EER2, or HSPF2. This refers to the 2024 HVAC efficiency standards and reflects the most current testing conditions. Remember that different regions have different standards even though the DOE regulates efficiency on a national level. Understanding your local requirements is the best way to reduce HVAC energy costs and overall energy usage.

What Are the New HVAC Regulations for 2024?

A new HVAC system must meet the requirements below to be sold or installed in the United States. 

Efficiency ratings are regional, so the new HVAC regulations for 2024 depend on where you live. New air conditioners in Northern regions must have a minimum SEER rating of 14. In Southern regions, the minimum SEER rating is 15 for most units.

Nationwide, new air-source heat pumps are subject to a minimum 8.8 HSPF, while new furnaces must have at least an 81% AFUE. The DOE also introduced new testing conditions, so you’ll notice a lower minimum number for SEER2, EER2, and HSPF2 compared to the equivalent SEER, EER, and HSPF.

Minimum SEER Rating for 2024

On January 1, 2023, SEER ratings for Northern states increased from 13 SEER to 14 SEER for split-system ACs or single-package ACs. Southern and Southwest regions increased SEER minimums based on the unit size. Meanwhile, split-system heat pumps have a new nationwide minimum of 15 SEER. These minimums are still in effect for 2024.

Type of System2024 Minimum SEER Rating (Northern Regions)2024 Minimum SEER Rating (Southeast and Southwest Regions)
AC (<45,000 BTU/hr)14 SEER (13.4 SEER2)15 SEER (14.3 SEER2)
AC (>45,000 BTU/hr)14 SEER (13.4 SEER2)14.5 SEER (13.8 SEER2)
Split-System Heat Pump15 SEER (14.3 SEER2)15 SEER (14.3 SEER2)
Single-Package Heat PumpNo ChangeNo Change

HSPF for 2024

In addition to a SEER rating, heat pumps also have an HSPF rating. This measures their heating efficiency. You can reduce the cost of ductless heating and cooling systems by having high SEER and HSPF ratings.

Type of Heat Pump2024 Minimum HSPF Rating (Northern Regions)2024 Minimum HSPF Rating (Southeast and Southwest Regions)
Split-System Heat Pump8.8 HSPF (7.5 HSPF2)8.8 HSPF (7.5 HSPF2)
Single-Package Heat PumpNo ChangeNo Change

2024 Furnace Rating Standards

A technician inspecting a furnace
Photo: GregorBister / E+ / Getty Images

If you use a furnace for your home’s heat, pay attention to the AFUE. The minimum AFUE does not vary by region. For Northern, Southeast, and Southwest regions, the 2013 minimum AFUE rating is 81%. 

Sell Through Standards

Each region has different rules for whether or not homeowners can buy or install older systems that don’t meet the HVAC efficiency standards. For example, an HVAC tech in Ohio can buy and install a less efficient AC if it was compliant when manufactured. Meanwhile, in Florida, you can only buy and install an AC that meets 2024 requirements, even if it met efficiency standards when it was manufactured. Here’s an overview:

  • Northern Regions: Non-compliant air conditioners and heat pumps can be sold and installed if manufactured before January 1, 2023.

  • Southern Regions: Non-compliant air conditioners cannot be sold or installed regardless of the manufacture date. However, you can buy or install non-compliant heat pumps if manufactured before January 1, 2023.

  • Southwest Regions: Non-compliant air conditioners cannot be sold or installed regardless of the manufacture date. However, you can buy or install a non-compliant heat pump if manufactured before January 1, 2023.

New Testing Conditions for HVAC

Test ratings changed in 2023 and are still active for 2024, with new testing conditions, data values, and metrics to more accurately determine how an installed HVAC system performs. Instead of SEER, EER, and HSPF, the new values will be SEER2, EER2, and HSPF2. 

The increased testing involves increasing the unit’s external static pressure from 0.1 inches of water to 0.5 inches of water, which is more reflective of a real-life scenario with your new unit. The reason behind these HVAC regulatory changes is that the 2015 SEER testing isn’t an accurate representation of how external static pressure and the ductwork in your home affect an HVAC product. 

These new requirements mean that the manufacturers of HVAC systems must redesign any appliances that don’t meet these more rigorous requirements.

2024 Regional Standards for Split System HVAC Systems

You’ll see changes to regional standards for HVAC systems through new efficiency standards and an upgrade to older metric systems.

Below is a comparison of SEER, EER, and HSPF ratings to SEER2, EER2, and HSPF2 ratings:

  1. Southeast Regions: New SEER2 of 14.3 (or 15.0 SEER) for split system ACs less than 45K Btu/h, and 13.8 SEER2 (14.5 SEER) for split system ACs greater than 45K Btu/h

  2. Southwest Regions: New SEER2 of 14.3 (15 SEER) and 11.7 EER2 (12.2 EER) for split systems less than 45K Btu/h, and 13.8 SEER2 (14.5 SEER) and 11.2 EERs (11.7 EER) for split systems greater than 45K Btu/h

  3. Northern Regions: New SEER2 rating of 13.4 SEER2 (or 15.0 SEER) for all split AC systems

2024 National Standards for Split System Heat Pumps

New efficiency standards for heat pump systems will also increase to 14.3 SEER2, which is equivalent to 15.0 SEER and 7.5 HSPF2, or 8.8 HSPF. Keep in mind that heat pumps that were built before 2023 are still eligible for installation in 2024.

2024 National Standards for Packaged Systems 

While packaged systems aren’t seeing an increase in efficiency requirements, they will need to pass the new SEER2 and HSPF2 testing protocols, which include a 13.4 SEER2 rating and 6.7 HSPF2, or 14.0 SEER and 8.0 HSPF, respectively.

What These New Standards Mean for Homeowners

When purchasing a new air conditioner, heat pump, or packaged system, keeping these updated efficiency standards in mind is essential. Higher-performing units can be more costly than older units or units with lower SEER, EER, or HSPF ratings; for each increase in SEER rating, expect to pay anywhere from $350 to $1,500 more. 

But remember, the improved performance and monetary benefits of choosing a high-efficiency heating or cooling system may save you money in the long run. The Office of Energy Efficiency and Renewable Energy states that heating and cooling account for 55% of the energy used in residential homes. So, maximizing efficiency is a good way to keep money in your pocket at the end of each month.

If your HVAC unit is due for an upgrade, consider installing a high-efficiency HVAC system or adding an ERV system to improve HVAC performance. A local HVAC service can help you choose the best option for your home.

Allie Ogletree contributed to this piece.

Frequently Asked Questions

Homeowners may qualify for an HVAC tax credit if they install an ENERGY STAR®-certified HVAC system that exceeds the energy efficiency minimum standards:

  • Split-System AC: 16 SEER2

  • Packaged AC: 15.2 SEER2 and 11.5 EER2

  • Ducted Split Heat Pump: 15.2 SEER2, 7.8 HSPF2, and 11.7 EER2 

  • Packaged Heat Pump: 15.2 SEER2, 7.2 HSPF2, and 10.6 EER2

  • Mini-Split System: 16 SEER2, 9 HSPF2, and 12 EER2

You can claim up to 30% of the cost of the job, subject to maximums.

Need professional help with your project?
Get quotes from top-rated pros.
Learn more about our contributor
Mariel Loveland
Written by Mariel Loveland
Contributing Writer
Mariel is a writer from New York City who has a passion for helping renters and homeowners make their space unapologetically their own—and save a few bucks along the way.
Mariel is a writer from New York City who has a passion for helping renters and homeowners make their space unapologetically their own—and save a few bucks along the way.
The homeowners guide to Energy Efficiency Auditing
From average costs to expert advice, get all the answers you need to get your job done.