Electrically driven lower limb exoskeleton rehabilitation robot based on anthropomorphic design
M Gao, Z Wang, Z Pang, J Sun, J Li, S Li, H Zhang - Machines, 2022 - mdpi.com
M Gao, Z Wang, Z Pang, J Sun, J Li, S Li, H Zhang
Machines, 2022•mdpi.comTo help people with impairment of lower extremity movement regain the ability to stand and
walk, and to enhance limb function, this study proposes an anthropomorphic design of an
electrically driven, lower-limb exoskeleton rehabilitation robot. The angular range of the
robot's motion was determined according to the characteristics of the targeted lower-limb
joints; the robot was given an active–passive anthropomorphic design with 12 degrees of
freedom. The multi-degree-of-freedom hip exoskeleton, bionic artificial knee exoskeleton …
walk, and to enhance limb function, this study proposes an anthropomorphic design of an
electrically driven, lower-limb exoskeleton rehabilitation robot. The angular range of the
robot's motion was determined according to the characteristics of the targeted lower-limb
joints; the robot was given an active–passive anthropomorphic design with 12 degrees of
freedom. The multi-degree-of-freedom hip exoskeleton, bionic artificial knee exoskeleton …
To help people with impairment of lower extremity movement regain the ability to stand and walk, and to enhance limb function, this study proposes an anthropomorphic design of an electrically driven, lower-limb exoskeleton rehabilitation robot. The angular range of the robot’s motion was determined according to the characteristics of the targeted lower-limb joints; the robot was given an active–passive anthropomorphic design with 12 degrees of freedom. The multi-degree-of-freedom hip exoskeleton, bionic artificial knee exoskeleton and passive rigid-flexible coupling ankle exoskeleton can assist patients in rehabilitation exercises with better wear comfort and exercise flexibility. A kinetic model of the seven-rod lower-limb exoskeleton rehabilitation robot was built, and data analysis of the dynamically captured motion trajectory was conducted. These provided a theoretical basis for gait planning and the control system of the lower-limb exoskeleton rehabilitation robot. The results show that the lower-limb exoskeleton rehabilitation robot system possesses sound wearing comfort and movement flexibility, and the degree of freedom of movement of the exoskeleton robot matches well with that of human movement. The robot can thus provide effective assistance to patients’ standing and walking rehabilitation training.
MDPI
Showing the best result for this search. See all results