IEICE Electronics Express
Online ISSN : 1349-2543
ISSN-L : 1349-2543
LETTER
Alternative method for the determination of the ideal electromagnetic reverberant frequency with frequency stirring technique
Shouyang ZhaiXiang ZhouPeng HuYan ChenDan ChenZhongyuan ZhouMingjie Sheng
Author information
JOURNAL FREE ACCESS

2021 Volume 18 Issue 6 Pages 20210069

Details
Abstract

For arbitrary electrically large cavities, the ideal reverberant frequency is of critical to predict the response of the reference antenna or the electronics inside. To determine the ideal reverberant frequency, this work has carried out a comparison study on the scattering parameter S11 and S21 based methods for the general case in reverberation chamber (RC). For the two methods, both of them share the same theoretical basis according to the ergodicity principle, i.e., the ideal field distribution and the commonly used correlation analysis. While for arbitrary electrically large cavities, the S11 samples rely on the mechanical stirrer (which is not easy to be equipped like that of a classic RC), S21 samples are more easily recorded by frequency stirring technique. And the corresponding experimental results show that the S21 based method can provide a more conservative estimate of the ideal reverberant frequency.

Content from these authors
© 2021 by The Institute of Electronics, Information and Communication Engineers