11 pages, 561 KiB  
Article
Association Between Cognitive Function and the Autonomic Nervous System by Photoplethysmography
by Jaewook Jin, Kahye Kim, KunHo Lee, Jeong-Woo Seo and Jaeuk U. Kim
Bioengineering 2024, 11(11), 1099; https://doi.org/10.3390/bioengineering11111099 - 1 Nov 2024
Viewed by 1035
Abstract
This study explored the relationship between cognitive function and the autonomic nervous system by categorizing participants into two groups based on their cognitive function scores in each domain of the SNSB-D: a High Cognitive Performance (HCP) group and a Low Cognitive Performance (LCP) [...] Read more.
This study explored the relationship between cognitive function and the autonomic nervous system by categorizing participants into two groups based on their cognitive function scores in each domain of the SNSB-D: a High Cognitive Performance (HCP) group and a Low Cognitive Performance (LCP) group. We analyzed the Pulse Rate Variability (PRV) parameters for each group. Photoplethysmography (PPG) data were collected and processed to remove noise, and the PRV parameters in the time and frequency domains were extracted. To minimize the impact of age and years of education on the PRV parameters, we performed an adjusted analysis using a Generalized Linear Model (GLM). The analysis revealed that the autonomic nervous system, particularly the parasympathetic nervous system, was more activated in the LCP group compared to the HCP group. This finding suggests that in individuals with low cognitive function, the sympathetic nerves in the autonomic nervous system are less activated, so the parasympathetic nerves are relatively more activated. This study investigated the correlation between cognitive function and PRV parameters, highlighting the potential use of these parameters as indicators for the early diagnosis and classification of cognitive decline. Full article
(This article belongs to the Section Biosignal Processing)
Show Figures

Figure 1

21 pages, 4535 KiB  
Article
Wearable Ring-Shaped Biomedical Device for Physiological Monitoring through Finger-Based Acquisition of Electrocardiographic, Photoplethysmographic, and Galvanic Skin Response Signals: Design and Preliminary Measurements
by Gabriele Volpes, Simone Valenti, Giuseppe Genova, Chiara Barà, Antonino Parisi, Luca Faes, Alessandro Busacca and Riccardo Pernice
Biosensors 2024, 14(4), 205; https://doi.org/10.3390/bios14040205 - 20 Apr 2024
Cited by 3 | Viewed by 3833
Abstract
Wearable health devices (WHDs) are rapidly gaining ground in the biomedical field due to their ability to monitor the individual physiological state in everyday life scenarios, while providing a comfortable wear experience. This study introduces a novel wearable biomedical device capable of synchronously [...] Read more.
Wearable health devices (WHDs) are rapidly gaining ground in the biomedical field due to their ability to monitor the individual physiological state in everyday life scenarios, while providing a comfortable wear experience. This study introduces a novel wearable biomedical device capable of synchronously acquiring electrocardiographic (ECG), photoplethysmographic (PPG), galvanic skin response (GSR) and motion signals. The device has been specifically designed to be worn on a finger, enabling the acquisition of all biosignals directly on the fingertips, offering the significant advantage of being very comfortable and easy to be employed by the users. The simultaneous acquisition of different biosignals allows the extraction of important physiological indices, such as heart rate (HR) and its variability (HRV), pulse arrival time (PAT), GSR level, blood oxygenation level (SpO2), and respiratory rate, as well as motion detection, enabling the assessment of physiological states, together with the detection of potential physical and mental stress conditions. Preliminary measurements have been conducted on healthy subjects using a measurement protocol consisting of resting states (i.e., SUPINE and SIT) alternated with physiological stress conditions (i.e., STAND and WALK). Statistical analyses have been carried out among the distributions of the physiological indices extracted in time, frequency, and information domains, evaluated under different physiological conditions. The results of our analyses demonstrate the capability of the device to detect changes between rest and stress conditions, thereby encouraging its use for assessing individuals’ physiological state. Furthermore, the possibility of performing synchronous acquisitions of PPG and ECG signals has allowed us to compare HRV and pulse rate variability (PRV) indices, so as to corroborate the reliability of PRV analysis under stationary physical conditions. Finally, the study confirms the already known limitations of wearable devices during physical activities, suggesting the use of algorithms for motion artifact correction. Full article
Show Figures

Figure 1

20 pages, 4587 KiB  
Article
Heart Rate Variability and Pulse Rate Variability: Do Anatomical Location and Sampling Rate Matter?
by Joel S. Burma, James K. Griffiths, Andrew P. Lapointe, Ibukunoluwa K. Oni, Ateyeh Soroush, Joseph Carere, Jonathan D. Smirl and Jeff F. Dunn
Sensors 2024, 24(7), 2048; https://doi.org/10.3390/s24072048 - 23 Mar 2024
Cited by 2 | Viewed by 2460
Abstract
Wearable technology and neuroimaging equipment using photoplethysmography (PPG) have become increasingly popularized in recent years. Several investigations deriving pulse rate variability (PRV) from PPG have demonstrated that a slight bias exists compared to concurrent heart rate variability (HRV) estimates. PPG devices commonly sample [...] Read more.
Wearable technology and neuroimaging equipment using photoplethysmography (PPG) have become increasingly popularized in recent years. Several investigations deriving pulse rate variability (PRV) from PPG have demonstrated that a slight bias exists compared to concurrent heart rate variability (HRV) estimates. PPG devices commonly sample at ~20–100 Hz, where the minimum sampling frequency to derive valid PRV metrics is unknown. Further, due to different autonomic innervation, it is unknown if PRV metrics are harmonious between the cerebral and peripheral vasculature. Cardiac activity via electrocardiography (ECG) and PPG were obtained concurrently in 54 participants (29 females) in an upright orthostatic position. PPG data were collected at three anatomical locations: left third phalanx, middle cerebral artery, and posterior cerebral artery using a Finapres NOVA device and transcranial Doppler ultrasound. Data were sampled for five minutes at 1000 Hz and downsampled to frequencies ranging from 20 to 500 Hz. HRV (via ECG) and PRV (via PPG) were quantified and compared at 1000 Hz using Bland–Altman plots and coefficient of variation (CoV). A sampling frequency of ~100–200 Hz was required to produce PRV metrics with a bias of less than 2%, while a sampling rate of ~40–50 Hz elicited a bias smaller than 20%. At 1000 Hz, time- and frequency-domain PRV measures were slightly elevated compared to those derived from HRV (mean bias: ~1–8%). In conjunction with previous reports, PRV and HRV were not surrogate biomarkers due to the different nature of the collected waveforms. Nevertheless, PRV estimates displayed greater validity at a lower sampling rate compared to HRV estimates. Full article
Show Figures

Figure 1

11 pages, 1911 KiB  
Brief Report
Autonomic and Vascular Responses during Reactive Hyperemia in Healthy Individuals and Patients with Sickle Cell Anemia
by Erislandis López-Galán, Adrián Alejandro Vitón-Castillo, Ramón Carrazana-Escalona, Maylet Planas-Rodriguez, Adolfo Arsenio Fernández-García, Ileana Cutiño-Clavel, Alexander Pascau-Simon, Philippe Connes, Miguel Enrique Sánchez-Hechavarría and Gustavo Alejandro Muñoz-Bustos
Medicina 2023, 59(6), 1141; https://doi.org/10.3390/medicina59061141 - 13 Jun 2023
Cited by 1 | Viewed by 2607
Abstract
Background and Objectives: To compare autonomic and vascular responses during reactive hyperemia (RH) between healthy individuals and patients with sickle cell anemia (SCA). Materials and Methods: Eighteen healthy subjects and 24 SCA patients were subjected to arterial occlusion for 3 min at the [...] Read more.
Background and Objectives: To compare autonomic and vascular responses during reactive hyperemia (RH) between healthy individuals and patients with sickle cell anemia (SCA). Materials and Methods: Eighteen healthy subjects and 24 SCA patients were subjected to arterial occlusion for 3 min at the lower right limb level. The pulse rate variability (PRV) and pulse wave amplitude were measured through photoplethysmography using the Angiodin® PD 3000 device, which was placed on the first finger of the lower right limb 2 min before (Basal) and 2 min after the occlusion. Pulse peak intervals were analyzed using time–frequency (wavelet transform) methods for high-frequency (HF: 0.15–0.4) and low-frequency (LF: 0.04–0.15) bands, and the LF/HF ratio was calculated. Results: The pulse wave amplitude was higher in healthy subjects compared to SCA patients, at both baseline and post-occlusion (p < 0.05). Time–frequency analysis showed that the LF/HF peak in response to the post-occlusion RH test was reached earlier in healthy subjects compared to SCA patients. Conclusions: Vasodilatory function, as measured by PPG, was lower in SCA patients compared to healthy subjects. Moreover, a cardiovascular autonomic imbalance was present in SCA patients with high sympathetic and low parasympathetic activity in the basal state and a poor response of the sympathetic nervous system to RH. Early cardiovascular sympathetic activation (10 s) and vasodilatory function in response to RH were impaired in SCA patients. Full article
(This article belongs to the Special Issue Sickle Cell Disease and the COVID-19 Pandemic)
Show Figures

Figure 1

16 pages, 6022 KiB  
Article
Experimental Verification of the Possibility of Reducing Photoplethysmography Measurement Time for Stress Index Calculation
by Seung-Gun Lee, Young Do Song and Eui Chul Lee
Sensors 2023, 23(12), 5511; https://doi.org/10.3390/s23125511 - 12 Jun 2023
Cited by 5 | Viewed by 2234
Abstract
Stress is a direct or indirect cause of reduced work efficiency in daily life. It can damage physical and mental health, leading to cardiovascular disease and depression. With increased interest and awareness of the risks of stress in modern society, there is a [...] Read more.
Stress is a direct or indirect cause of reduced work efficiency in daily life. It can damage physical and mental health, leading to cardiovascular disease and depression. With increased interest and awareness of the risks of stress in modern society, there is a growing demand for quick assessment and monitoring of stress levels. Traditional ultra-short-term stress measurement classifies stress situations using heart rate variability (HRV) or pulse rate variability (PRV) information extracted from electrocardiogram (ECG) or photoplethysmography (PPG) signals. However, it requires more than one minute, making it difficult to monitor stress status in real-time and accurately predict stress levels. In this paper, stress indices were predicted using PRV indices acquired at different lengths of time (60 s, 50 s, 40 s, 30 s, 20 s, 10 s, and 5 s) for the purpose of real-time stress monitoring. Stress was predicted with Extra Tree Regressor, Random Forest Regressor, and Gradient Boost Regressor models using a valid PRV index for each data acquisition time. The predicted stress index was evaluated using an R2 score between the predicted stress index and the actual stress index calculated from one minute of the PPG signal. The average R2 score of the three models by the data acquisition time was 0.2194 at 5 s, 0.7600 at 10 s, 0.8846 at 20 s, 0.9263 at 30 s, 0.9501 at 40 s, 0.9733 at 50 s, and 0.9909 at 60 s. Thus, when stress was predicted using PPG data acquired for 10 s or more, the R2 score was confirmed to be over 0.7. Full article
(This article belongs to the Special Issue Biomedical Signal Processing and Health Monitoring Based on Sensors)
Show Figures

Figure 1

20 pages, 4289 KiB  
Article
Induced Relaxation Enhances the Cardiorespiratory Dynamics in COVID-19 Survivors
by Alejandra Margarita Sánchez-Solís, Viridiana Peláez-Hernández, Laura Mercedes Santiago-Fuentes, Guadalupe Lizzbett Luna-Rodríguez, José Javier Reyes-Lagos and Arturo Orea-Tejeda
Entropy 2023, 25(6), 874; https://doi.org/10.3390/e25060874 - 30 May 2023
Cited by 3 | Viewed by 2277
Abstract
Most COVID-19 survivors report experiencing at least one persistent symptom after recovery, including sympathovagal imbalance. Relaxation techniques based on slow-paced breathing have proven to be beneficial for cardiovascular and respiratory dynamics in healthy subjects and patients with various diseases. Therefore, the present study [...] Read more.
Most COVID-19 survivors report experiencing at least one persistent symptom after recovery, including sympathovagal imbalance. Relaxation techniques based on slow-paced breathing have proven to be beneficial for cardiovascular and respiratory dynamics in healthy subjects and patients with various diseases. Therefore, the present study aimed to explore the cardiorespiratory dynamics by linear and nonlinear analysis of photoplethysmographic and respiratory time series on COVID-19 survivors under a psychophysiological assessment that includes slow-paced breathing. We analyzed photoplethysmographic and respiratory signals of 49 COVID-19 survivors to assess breathing rate variability (BRV), pulse rate variability (PRV), and pulse–respiration quotient (PRQ) during a psychophysiological assessment. Additionally, a comorbidity-based analysis was conducted to evaluate group changes. Our results indicate that all BRV indices significantly differed when performing slow-paced breathing. Nonlinear parameters of PRV were more appropriate for identifying changes in breathing patterns than linear indices. Furthermore, the mean and standard deviation of PRQ exhibited a significant increase while sample and fuzzy entropies decreased during diaphragmatic breathing. Thus, our findings suggest that slow-paced breathing may improve the cardiorespiratory dynamics of COVID-19 survivors in the short term by enhancing cardiorespiratory coupling via increased vagal activity. Full article
(This article belongs to the Special Issue Nonlinear Dynamics in Cardiovascular Signals)
Show Figures

Figure 1

17 pages, 4598 KiB  
Article
Real-Time Evaluation of Time-Domain Pulse Rate Variability Parameters in Different Postures and Breathing Patterns Using Wireless Photoplethysmography Sensor: Towards Remote Healthcare in Low-Resource Communities
by Felipe Pineda-Alpizar, Sergio Arriola-Valverde, Mitzy Vado-Chacón, Diego Sossa-Rojas, Haipeng Liu and Dingchang Zheng
Sensors 2023, 23(9), 4246; https://doi.org/10.3390/s23094246 - 24 Apr 2023
Cited by 2 | Viewed by 3246
Abstract
Photoplethysmography (PPG) signals have been widely used in evaluating cardiovascular biomarkers, however, there is a lack of in-depth understanding of the remote usage of this technology and its viability for underdeveloped countries. This study aims to quantitatively evaluate the performance of a low-cost [...] Read more.
Photoplethysmography (PPG) signals have been widely used in evaluating cardiovascular biomarkers, however, there is a lack of in-depth understanding of the remote usage of this technology and its viability for underdeveloped countries. This study aims to quantitatively evaluate the performance of a low-cost wireless PPG device in detecting ultra-short-term time-domain pulse rate variability (PRV) parameters in different postures and breathing patterns. A total of 30 healthy subjects were recruited. ECG and PPG signals were simultaneously recorded in 3 min using miniaturized wearable sensors. Four heart rate variability (HRV) and PRV parameters were extracted from ECG and PPG signals, respectively, and compared using analysis of variance (ANOVA) or Scheirer–Ray–Hare test with post hoc analysis. In addition, the data loss was calculated as the percentage of missing sampling points. Posture did not present statistical differences across the PRV parameters but a statistical difference between indicators was found. Strong variation was found for the RMSSD indicator in the standing posture. The sitting position in both breathing patterns demonstrated the lowest data loss (1.0 ± 0.6 and 1.0 ± 0.7) and the lowest percentage of different factors for all indicators. The usage of commercial PPG and BLE devices can allow the reliable extraction of the PPG signal and PRV indicators in real time. Full article
Show Figures

Figure 1

18 pages, 1243 KiB  
Article
Contactless Cardiovascular Assessment by Imaging Photoplethysmography: A Comparison with Wearable Monitoring
by Valerie A. A. van Es, Richard G. P. Lopata, Enzo Pasquale Scilingo and Mimma Nardelli
Sensors 2023, 23(3), 1505; https://doi.org/10.3390/s23031505 - 29 Jan 2023
Cited by 17 | Viewed by 3306
Abstract
Despite the notable recent developments in the field of remote photoplethysmography (rPPG), extracting a reliable pulse rate variability (PRV) signal still remains a challenge. In this study, eight image-based photoplethysmography (iPPG) extraction methods (GRD, AGRD, PCA, ICA, LE, SPE, CHROM, and POS) were [...] Read more.
Despite the notable recent developments in the field of remote photoplethysmography (rPPG), extracting a reliable pulse rate variability (PRV) signal still remains a challenge. In this study, eight image-based photoplethysmography (iPPG) extraction methods (GRD, AGRD, PCA, ICA, LE, SPE, CHROM, and POS) were compared in terms of pulse rate (PR) and PRV features. The algorithms were made robust for motion and illumination artifacts by using ad hoc pre- and postprocessing steps. Then, they were systematically tested on the public dataset UBFC-RPPG, containing data from 42 subjects sitting in front of a webcam (30 fps) while playing a time-sensitive mathematical game. The performances of the algorithms were evaluated by statistically comparing iPPG-based and finger-PPG-based PR and PRV features in terms of Spearman’s correlation coefficient, normalized root mean square error (NRMSE), and Bland–Altman analysis. The study revealed POS and CHROM techniques to be the most robust for PR estimation and the assessment of overall autonomic nervous system (ANS) dynamics by using PRV features in time and frequency domains. Furthermore, we demonstrated that a reliable characterization of the vagal tone is made possible by computing the Poincaré map of PRV series derived from the POS and CHROM methods. This study supports the use of iPPG systems as promising tools to obtain clinically useful and specific information about ANS dynamics. Full article
Show Figures

Figure 1

21 pages, 1211 KiB  
Article
Processing Photoplethysmograms Recorded by Smartwatches to Improve the Quality of Derived Pulse Rate Variability
by Adam G. Polak, Bartłomiej Klich, Stanisław Saganowski, Monika A. Prucnal and Przemysław Kazienko
Sensors 2022, 22(18), 7047; https://doi.org/10.3390/s22187047 - 17 Sep 2022
Cited by 8 | Viewed by 2910
Abstract
Cardiac monitoring based on wearable photoplethysmography (PPG) is widespread because of its usability and low cost. Unfortunately, PPG is negatively affected by various types of disruptions, which could introduce errors to the algorithm that extracts pulse rate variability (PRV). This study aims to [...] Read more.
Cardiac monitoring based on wearable photoplethysmography (PPG) is widespread because of its usability and low cost. Unfortunately, PPG is negatively affected by various types of disruptions, which could introduce errors to the algorithm that extracts pulse rate variability (PRV). This study aims to identify the nature of such artifacts caused by various types of factors under the conditions of precisely planned experiments. We also propose methods for their reduction based solely on the PPG signal while preserving the frequency content of PRV. The accuracy of PRV derived from PPG was compared to heart rate variability (HRV) derived from the accompanying ECG. The results indicate that filtering PPG signals using the discrete wavelet transform and its inverse (DWT/IDWT) is suitable for removing slow components and high-frequency noise. Moreover, the main benefit of amplitude demodulation is better preparation of the PPG to determine the duration of pulse cycles and reduce the impact of some other artifacts. Post-processing applied to HRV and PRV indicates that the correction of outliers based on local statistical measures of signals and the autoregressive (AR) model is only important when the PPG is of low quality and has no effect under good signal quality. The main conclusion is that the DWT/IDWT, followed by amplitude demodulation, enables the proper preparation of the PPG signal for the subsequent use of PRV extraction algorithms, particularly at rest. However, post-processing in the proposed form should be applied more in the situations of observed strong artifacts than in motionless laboratory experiments. Full article
Show Figures

Figure 1

26 pages, 3662 KiB  
Article
Photoplethysmography-Based Pulse Rate Variability and Haemodynamic Changes in the Absence of Heart Rate Variability: An In-Vitro Study
by Elisa Mejía-Mejía and Panicos A. Kyriacou
Appl. Sci. 2022, 12(14), 7238; https://doi.org/10.3390/app12147238 - 18 Jul 2022
Cited by 1 | Viewed by 1664
Abstract
Pulse rate variability (PRV), measured from pulsatile signals such as the photoplethysmogram (PPG), has been largely used in recent years as a surrogate of heart rate variability (HRV), which is measured from electrocardiograms (ECG). However, different studies have shown that PRV does not [...] Read more.
Pulse rate variability (PRV), measured from pulsatile signals such as the photoplethysmogram (PPG), has been largely used in recent years as a surrogate of heart rate variability (HRV), which is measured from electrocardiograms (ECG). However, different studies have shown that PRV does not always replicate HRV as there are multiple factors that could affect their relationship, such as respiration and pulse transit time. In this study, an in-vitro model was developed for the simulation of the upper-circulatory system, and PPG signals were acquired from it when haemodynamic changes were induced. PRV was obtained from these signals and time-domain, frequency-domain and non-linear indices were extracted. Factorial analyses were performed to understand the effects of changing blood pressure and flow on PRV indices in the absence of HRV. Results showed that PRV indices are affected by these haemodynamic changes and that these may explain some of the differences between HRV and PRV. Future studies should aim to replicate these results in healthy volunteers and patients, as well as to include the HRV information in the in-vitro model for a more profound understanding of these differences. Full article
Show Figures

Figure 1

24 pages, 3236 KiB  
Article
Atrial Fibrillation Classification with Smart Wearables Using Short-Term Heart Rate Variability and Deep Convolutional Neural Networks
by Jayroop Ramesh, Zahra Solatidehkordi, Raafat Aburukba and Assim Sagahyroon
Sensors 2021, 21(21), 7233; https://doi.org/10.3390/s21217233 - 30 Oct 2021
Cited by 32 | Viewed by 7738
Abstract
Atrial fibrillation (AF) is a type of cardiac arrhythmia affecting millions of people every year. This disease increases the likelihood of strokes, heart failure, and even death. While dedicated medical-grade electrocardiogram (ECG) devices can enable gold-standard analysis, these devices are expensive and require [...] Read more.
Atrial fibrillation (AF) is a type of cardiac arrhythmia affecting millions of people every year. This disease increases the likelihood of strokes, heart failure, and even death. While dedicated medical-grade electrocardiogram (ECG) devices can enable gold-standard analysis, these devices are expensive and require clinical settings. Recent advances in the capabilities of general-purpose smartphones and wearable technology equipped with photoplethysmography (PPG) sensors increase diagnostic accessibility for most populations. This work aims to develop a single model that can generalize AF classification across the modalities of ECG and PPG with a unified knowledge representation. This is enabled by approximating the transformation of signals obtained from low-cost wearable PPG sensors in terms of Pulse Rate Variability (PRV) to temporal Heart Rate Variability (HRV) features extracted from medical-grade ECG. This paper proposes a one-dimensional deep convolutional neural network that uses HRV-derived features for classifying 30-s heart rhythms as normal sinus rhythm or atrial fibrillation from both ECG and PPG-based sensors. The model is trained with three MIT-BIH ECG databases and is assessed on a dataset of unseen PPG signals acquired from wrist-worn wearable devices through transfer learning. The model achieved the aggregate binary classification performance measures of accuracy: 95.50%, sensitivity: 94.50%, and specificity: 96.00% across a five-fold cross-validation strategy on the ECG datasets. It also achieved 95.10% accuracy, 94.60% sensitivity, 95.20% specificity on an unseen PPG dataset. The results show considerable promise towards seamless adaptation of gold-standard ECG trained models for non-ambulatory AF detection with consumer wearable devices through HRV-based knowledge transfer. Full article
(This article belongs to the Special Issue Computer Aided Diagnosis Sensors)
Show Figures

Figure 1

15 pages, 7725 KiB  
Communication
Pulse Rate Variability Analysis Using Remote Photoplethysmography Signals
by Su-Gyeong Yu, So-Eui Kim, Na Hye Kim, Kun Ha Suh and Eui Chul Lee
Sensors 2021, 21(18), 6241; https://doi.org/10.3390/s21186241 - 17 Sep 2021
Cited by 22 | Viewed by 5199
Abstract
Pulse rate variability (PRV) refers to the change in the interval between pulses in the blood volume pulse (BVP) signal acquired using photoplethysmography (PPG). PRV is an indicator of the health status of an individual’s autonomic nervous system. A representative method for measuring [...] Read more.
Pulse rate variability (PRV) refers to the change in the interval between pulses in the blood volume pulse (BVP) signal acquired using photoplethysmography (PPG). PRV is an indicator of the health status of an individual’s autonomic nervous system. A representative method for measuring BVP is contact PPG (CPPG). CPPG may cause discomfort to a user, because the sensor is attached to the finger for measurements. In contrast, noncontact remote PPG (RPPG) extracts BVP signals from face data using a camera without the need for a sensor. However, because the existing RPPG is a technology that extracts a single pulse rate rather than a continuous BVP signal, it is difficult to extract additional health status indicators. Therefore, in this study, PRV analysis is performed using lab-based RPPG technology that can yield continuous BVP signals. In addition, we intended to confirm that the analysis of PRV via RPPG can be performed with the same quality as analysis via CPPG. The experimental results confirmed that the temporal and frequency parameters of PRV extracted from RPPG and CPPG were similar. In terms of correlation, the PRVs of RPPG and CPPG yielded correlation coefficients between 0.98 and 1.0. Full article
Show Figures

Figure 1

17 pages, 2813 KiB  
Article
Multimodal Assessment of the Pulse Rate Variability Analysis Module of a Photoplethysmography-Based Telemedicine System
by Flóra Antali, Dániel Kulin, Konrád István Lucz, Balázs Szabó, László Szűcs, Sándor Kulin and Zsuzsanna Miklós
Sensors 2021, 21(16), 5544; https://doi.org/10.3390/s21165544 - 18 Aug 2021
Cited by 11 | Viewed by 4317
Abstract
Alterations of heart rate variability (HRV) are associated with various (patho)physiological conditions; therefore, HRV analysis has the potential to become a useful diagnostic module of wearable/telemedical devices to support remote cardiovascular/autonomic monitoring. Continuous pulse recordings obtained by photoplethysmography (PPG) can yield pulse rate [...] Read more.
Alterations of heart rate variability (HRV) are associated with various (patho)physiological conditions; therefore, HRV analysis has the potential to become a useful diagnostic module of wearable/telemedical devices to support remote cardiovascular/autonomic monitoring. Continuous pulse recordings obtained by photoplethysmography (PPG) can yield pulse rate variability (PRV) indices similar to HRV parameters; however, it is debated whether PRV/HRV parameters are interchangeable. In this study, we assessed the PRV analysis module of a digital arterial PPG-based telemedical system (SCN4ALL). We used Bland–Altman analysis to validate the SCN4ALL PRV algorithm to Kubios Premium software and to determine the agreements between PRV/HRV results calculated from 2-min long PPG and ECG captures recorded simultaneously in healthy individuals (n = 33) at rest and during the cold pressor test, and in diabetic patients (n = 12) at rest. We found an ideal agreement between SCN4ALL and Kubios outputs (bias < 2%). PRV and HRV parameters showed good agreements for interbeat intervals, SDNN, and RMSSD time-domain variables, for total spectral and low-frequency power (LF) frequency-domain variables, and for non-linear parameters in healthy subjects at rest and during cold pressor challenge. In diabetics, good agreements were observed for SDNN, LF, and SD2; and moderate agreement was observed for total power. In conclusion, the SCN4ALL PRV analysis module is a good alternative for HRV analysis for numerous conventional HRV parameters. Full article
Show Figures

Figure 1

17 pages, 2091 KiB  
Article
Assessment of Nocturnal Autonomic Cardiac Imbalance in Positional Obstructive Sleep Apnea. A Multiscale Nonlinear Approach
by Daniel Álvarez, C. Ainhoa Arroyo, Julio F. de Frutos, Andrea Crespo, Ana Cerezo-Hernández, Gonzalo C. Gutiérrez-Tobal, Fernando Vaquerizo-Villar, Verónica Barroso-García, Fernando Moreno, Tomás Ruiz, Roberto Hornero and Félix del Campo
Entropy 2020, 22(12), 1404; https://doi.org/10.3390/e22121404 - 12 Dec 2020
Cited by 7 | Viewed by 2644
Abstract
Positional obstructive sleep apnea (POSA) is a major phenotype of sleep apnea. Supine-predominant positional patients are frequently characterized by milder symptoms and less comorbidity due to a lower age, body mass index, and overall apnea-hypopnea index. However, the bradycardia-tachycardia pattern during apneic events [...] Read more.
Positional obstructive sleep apnea (POSA) is a major phenotype of sleep apnea. Supine-predominant positional patients are frequently characterized by milder symptoms and less comorbidity due to a lower age, body mass index, and overall apnea-hypopnea index. However, the bradycardia-tachycardia pattern during apneic events is known to be more severe in the supine position, which could affect the cardiac regulation of positional patients. This study aims at characterizing nocturnal heart rate modulation in the presence of POSA in order to assess potential differences between positional and non-positional patients. Patients showing clinical symptoms of suffering from a sleep-related breathing disorder performed unsupervised portable polysomnography (PSG) and simultaneous nocturnal pulse oximetry (NPO) at home. Positional patients were identified according to the Amsterdam POSA classification (APOC) criteria. Pulse rate variability (PRV) recordings from the NPO readings were used to assess overnight cardiac modulation. Conventional cardiac indexes in the time and frequency domains were computed. Additionally, multiscale entropy (MSE) was used to investigate the nonlinear dynamics of the PRV recordings in POSA and non-POSA patients. A total of 129 patients (median age 56.0, interquartile range (IQR) 44.8–63.0 years, median body mass index (BMI) 27.7, IQR 26.0–31.3 kg/m2) were classified as POSA (37 APOC I, 77 APOC II, and 15 APOC III), while 104 subjects (median age 57.5, IQR 49.0–67.0 years, median BMI 29.8, IQR 26.6–34.7 kg/m2) comprised the non-POSA group. Overnight PRV recordings from positional patients showed significantly higher disorderliness than non-positional subjects in the smallest biological scales of the MSE profile (τ = 1: 0.25, IQR 0.20–0.31 vs. 0.22, IQR 0.18–0.27, p < 0.01) (τ = 2: 0.41, IQR 0.34–0.48 vs. 0.37, IQR 0.29–0.42, p < 0.01). According to our findings, nocturnal heart rate regulation is severely affected in POSA patients, suggesting increased cardiac imbalance due to predominant positional apneas. Full article
(This article belongs to the Special Issue Entropy and Sleep Disorders II)
Show Figures

Figure 1

14 pages, 3790 KiB  
Article
Assessing the Quality of Heart Rate Variability Estimated from Wrist and Finger PPG: A Novel Approach Based on Cross-Mapping Method
by Mimma Nardelli, Nicola Vanello, Guenda Galperti, Alberto Greco and Enzo Pasquale Scilingo
Sensors 2020, 20(11), 3156; https://doi.org/10.3390/s20113156 - 2 Jun 2020
Cited by 35 | Viewed by 5086
Abstract
The non-invasiveness of photoplethysmographic (PPG) acquisition systems, together with their cost-effectiveness and easiness of connection with IoT technologies, is opening up to the possibility of their widespread use. For this reason, the study of the reliability of PPG and pulse rate variability (PRV) [...] Read more.
The non-invasiveness of photoplethysmographic (PPG) acquisition systems, together with their cost-effectiveness and easiness of connection with IoT technologies, is opening up to the possibility of their widespread use. For this reason, the study of the reliability of PPG and pulse rate variability (PRV) signal quality has become of great scientific, technological, and commercial interest. In this field, sensor location has been demonstrated to play a crucial role. The goal of this study was to investigate PPG and PRV signal quality acquired from two body locations: finger and wrist. We simultaneously acquired the PPG and electrocardiographic (ECG) signals from sixteen healthy subjects (aged 28.5 ± 3.5, seven females) who followed an experimental protocol of affective stimulation through visual stimuli. Statistical tests demonstrated that PPG signals acquired from the wrist and the finger presented different signal quality indexes (kurtosis and Shannon entropy), with higher values for the wrist-PPG. Then we propose to apply the cross-mapping (CM) approach as a new method to quantify the PRV signal quality. We found that the performance achieved using the two sites was significantly different in all the experimental sessions (p < 0.01), and the PRV dynamics acquired from the finger were the most similar to heart rate variability (HRV) dynamics. Full article
(This article belongs to the Section Wearables)