Iso-damping is a desirable system property refering to a state, where the phase Bode plot is flat, i.e., the phase derivative with respect to the frequency is zero, at a given frequency called the "tangent frequency" , . At the "tangent frequency" the Nyquist curve tangentially touches the sensitivity circle and the phase Bode is locally flat which implies that the system will be more robust to gain variations. For systems that exhibit iso-damping property, the overshoots of step responses will remain almost constant for different values of the controller gain. This will ensure that the closed-loop system is robust to gain variations. [1]

The iso-damping property can be expressed as , or equivalently:

,

where is the tangent frequency and is the open-loop system transfer function.

In the middle of the 20th century, Bode proposed the the first idea involving the use of fractional order controllers in a feedback problem by what is known as Bode’s Ideal Transfer Function. Bode proposed that the ideal shape of the open loop frequency response (Nyquist plot) is a straight line in the complex plane, which provides theoretically infinite gain margin. The major benefit achieved through this structure is iso-damping, i.e. overshoot being independent of the payload or the system gain. [2] The usage of fractional elements for description of ideal Bode's control loop is one of the most promising applications of fractional calculus in the process control field. Bode's ideal control loop frequency response has the fractional integrator shape and provides the iso-damping property. This is due to the fact that the phase margin and the maximum overshoot are defined by one parameter only (the fractional power of ), and are independent of open-loop gain.

References

  1. ^ YQ. Chen, C. Hu and K. L. Moore, "Relay Feedback Tuning of Robust PID Controllers With Iso-Damping Property," Proceedings of the 42nd IEEE Conference on Decision and Control. Maui, Hawaii USA, December 2003.
  2. ^ R.S. Barbosa, J.A.T. Machado and I.M. Ferreira, "Tuning of PID Controllers Based on Bode’s Ideal Transfer Function," Nonlinear Dynamics, Vol. 38, Issue 1, pp. 305-321, December 2004.